Description
A 60 mil composite sheet type waterproofing membrane consisting of 4 mils of cross laminated polyethylene film bonded to 56 mils of rubberized asphalt (modified bitumen) with a silicone release liner. Aquaflash 1000 forms a heavy duty barrier against physical damage and water migration.

Features/Benefits
• High temperature stability
Self-sealing
• Self-Healing
• High tensile strength

Uses
Aquaflash 1000 is used to waterproof both below and above grade for:
wood
concrete
masonry
Foundation Walls
Tunnels
Earth Shelters
Plaza Decks, Parking Decks, Structural Concrete Decks
Split slab construction- above/below grade
Approved Insulating Foams.

Application Summary
All surfaces to be waterproofed must be smooth, dry, dust and frost free. New structural concrete must be cured a minimum of seven days. Lightweight structural concrete must be cured a minimum of fourteen days. Aquaflash Primer must be applied to all substrates which are to be waterproofed. See Aquaflash Primer application sheet/data sheet.

For horizontal surfaces; Apply Aquaflash 1000 to the primed substrate starting at the lowest point. Successive sheets of Aquaflash 1000 should overlap preceding sheets by 2.5 inches. Remove the silicone coated release tapes for uniform lap adhesion. The membrane sheet should be firmly rolled to ensure uniform and complete contact with the substrate.

For vertical surfaces; Apply Aquaflash 1000 in manageable sections (8 ft.). On wall over 8 ft., it may be necessary to overlap adjoining sections. If applicable, the upper section should overlap the lower section by at least 2.5 inches. On successive vertical sections, remove the silicone coated release tapes for uniform lap adhesion. Use a hand roller to secure membrane too substrate. Use reglet, termination bar or counter flashing if terminated on a vertical surface.

Aquaflash 1000 is to be applied when substrate and ambient temperatures are 25 degrees Fahrenheit or above.

Warranty
Aquaflash 1000 waterproofing composite is warranted to be free from defects in manufacturing for a period of ten years. Material will be provided at no charge to replace any defective product. See sample warranty.

Maintenance
No maintenance required if installed per manufacturer’s instructions

Sizes
Rolls are 36 inches wide by 66.6 feet long. Approx. 200 square feet per roll or box

Technical Data

PROPERTY TEST METHOD NOMINAL VALUE
Tensile Strength Composite ASTM D412 325 lbs/in/sq
Tensile Strength/Film ASTM D412 5000 psi
Elongation to Break rubberized asphalt ASTM D412 300%
Pliability
180 degree bend 1” mandrel
At -25 degrees F
ASTM D416 Pass
Cycle over crack @ -25 F ASTM C836 Pass
Peel Adhesion/dry Concrete ASTM D903 10 lbs/in
Peel Adhesion/wet ASTM D903 9 lbs/in
Puncture Resistance ASTM E154 70 lbs
MVT ASTM E96 B 0.02 perms/max
Hydrostatic Resistance ASTM D751 210 ft