Description
A
60 mil composite sheet type waterproofing membrane consisting
of 4 mils of cross laminated polyethylene film bonded
to 56 mils of rubberized asphalt (modified bitumen)
with a silicone release liner. Aquaflash 1000 forms
a heavy duty barrier against physical damage and water
migration.
Features/Benefits
•
High temperature stability
• Self-sealing
•
Self-Healing
•
High tensile strength
Uses
Aquaflash
1000 is used to waterproof both below and above grade
for:
wood
concrete
masonry
Foundation Walls
Tunnels
Earth Shelters
Plaza Decks, Parking Decks, Structural Concrete Decks
Split slab construction- above/below grade
Approved Insulating Foams.
Application
Summary
All
surfaces to be waterproofed must be smooth, dry, dust
and frost free. New structural concrete must be cured
a minimum of seven days. Lightweight structural concrete
must be cured a minimum of fourteen days. Aquaflash
Primer must be applied to all substrates which are to
be waterproofed. See Aquaflash Primer application sheet/data
sheet.
For horizontal
surfaces; Apply Aquaflash 1000 to the primed substrate
starting at the lowest point. Successive sheets of Aquaflash 1000 should overlap preceding sheets by 2.5 inches.
Remove the silicone coated release tapes for uniform
lap adhesion. The membrane sheet should be firmly rolled
to ensure uniform and complete contact with the substrate.
For vertical
surfaces; Apply Aquaflash 1000 in manageable sections
(8 ft.). On wall over 8 ft., it may be necessary to
overlap adjoining sections. If applicable, the upper
section should overlap the lower section by at least
2.5 inches. On successive vertical sections, remove
the silicone coated release tapes for uniform lap adhesion.
Use a hand roller to secure membrane too substrate.
Use reglet, termination bar or counter flashing if terminated
on a vertical surface.
Aquaflash 1000 is to be applied when substrate and ambient
temperatures are 25 degrees Fahrenheit or above.
Warranty
Aquaflash
1000 waterproofing composite is warranted to be free
from defects in manufacturing for a period of ten years.
Material will be provided at no charge to replace any
defective product. See sample warranty.
Maintenance
No
maintenance required if installed per manufacturer’s
instructions
Sizes
Rolls
are 36 inches wide by 66.6 feet long. Approx. 200 square
feet per roll or box
Technical
Data
| PROPERTY |
TEST
METHOD |
NOMINAL
VALUE |
| Tensile
Strength Composite |
ASTM
D412 |
325
lbs/in/sq |
| Tensile
Strength/Film |
ASTM
D412 |
5000
psi |
| Elongation
to Break rubberized asphalt |
ASTM
D412 |
300% |
Pliability
180 degree bend 1” mandrel
At -25 degrees F |
ASTM
D416 |
Pass |
| Cycle
over crack @ -25 F |
ASTM
C836 |
Pass |
| Peel
Adhesion/dry Concrete |
ASTM
D903 |
10
lbs/in |
| Peel
Adhesion/wet |
ASTM
D903 |
9
lbs/in |
| Puncture
Resistance |
ASTM
E154 |
70
lbs |
| MVT
|
ASTM
E96 B |
0.02
perms/max |
| Hydrostatic
Resistance |
ASTM
D751 |
210
ft |
|