Installation:
Fiberweb is designed to be a protective membrane flashing' against surfaces of structural steel beams, steel lintels and other structural steel elements buried in masonry that needs protection from corrosion caused by penetrating moisture.

Thru-Wall Flashing: Starting 1/2" from face, bend flashing to form drip. Extend through veneer and turn up a minimum of 8".
For C.M.U. backup wall, bed flashing in the mortar joint closest to cavity and seal with a mastic. For wood, steel stud or framed back-up, seal into sheathing. Lap flashings around comers and at end joints a minimum of 6 inches and seal with an approved mastic.

Concealed Flashing:
Install at windows and doors as specified in spec plans using a
minimum of 6 inch strips of flashing at jambs and extending 4" above the head. At head. apply a 6" inch strip of flashing over jamb flashings. At sills, flash as for thru-wall installation instructions. Seal all laps with an approved mastic.

Outside Corners (Mitres- left to right):
Wrap flashing around, the comer, and starting 1/8" from the right side of the comer, cut flashing at crease to end of flashing. Secure Flashing into wall. Wrap the adjoining flashing from right of wall back around the flashing making the same incision as above and lap 6" over'the left side.

Apply Fiberweb tape at all laps and cut areas and then a coating of an approved mastic to ensure a long term seal.

Inside Corners (Mitres)
Wrap flashing around into comer. Starting 1/8" from innermost point of comer, make an incision in the flashing that extends to the outer edge. Wrap the left side of the incision
back over the right up to the bend and press a piece of the FIBER WEB tape over the entire length of the lap, ensuring that the innermost comer is sealed. Apply an approved mastic over the entire taped area to ensure a long term seal.
concrete specimens were prepared employing a mixture of Portland cement,

End Dams:
Where masonry meets another wall system, form an end dam by turning flashing up at least 6 ". Apply an approved
mastic over the entire taped area and seal to end masonry units.

Warranty:
Fiberweb products meet the specifications listed and they are tested to assure conformance to the physical properties listed herein. Fiberweb Corporation is not responsible for damage caused by improper use. handling and installation. The foregoing warranty is aU inclusive and is in lieu of aU other warranties whether written, oral, expressed or implied including any warranty or merchantability for purposes other than those advertised or depicted herein or warranty of fitness for a particular purpose. In no event shall Fiberweb Corporation be liable for incidental or consequential damages arising from its use.

Maintanence:
None required

Technical Services:
Tecbnical adVice and information may be obtained by calling or writing either the manufacturer or its distributors.